Name︰Emergency Power Supply
Model No.︰SL
Brand Name︰SPS
Product Description
Three phase output (T Series)

Use scope: mainly used in all three phase and single phase mixed load,such as elevator,wind turbine,water pump,light,air condition etc, applied in high floor building,fire establishment,hospital,airport,underground,power plant,supermarket,bank,negotiable securities etc.
OUTPUT POWER(KW):
2.2,3,3.7,5.5,6,7.5,11,15,18.5,20,22,25,30,37,40,45,55,75,80,93,100,110,120,132,150,160,187,200,220,250,280,315,400,500¡£
we can offer different specification.



Specifications
SE2.2KT~SE500KT

AC Input Allowable VoltageRange(V)
AC380/220+/-20%, Independent N Line and PE Line

AC Input Frequency((HZ)
45~65

AC Output Voltage(V)
When Normal Same as Utility Electricity;When emergency 380/ 220+/-3%

AC Output Frequency Tolerance((HZ)
50+/-0.05

AC Output Rated Power (kW)
2.2~500

Overload Capacity
120% Normal Operation:150%,30 Seconds

Inverter Efficiency(80% Resistance Load)
When electric utility.=100%(< =5%):When emergency> =90%

Wave shape Total Harmonic Distortion(THD)£¨Linear Load£©
< =3%

Dynamic Response (Load 0~100%)
5%

Protections
Output Overload, Output Short-Circuit,Overheat, Battery Overcharged, Battery Over discharged

Relay Device Switch Time
Static relay
< =10ms

Magnetic(Standard configure)
< =100ms

Battery Type
Valve-Control Non-Maintain Lead-Acid Battery or Non-Maintain Lead-Acid Battery

Backup Time
> 90 Minutes(Expendable)

Isolation Grade(VAC)(Input and Output)
2000,1 Minute

Noise(1Meter)
< or =55dB

Ambient Operation Temperature
-20°C~+50°C

Ambient Humidity
0~90%,Non-condensing

Altitude (m)
< 0r =2000


T Series dimension and weight:

CAPACITY(KW)
DimensionDxWxH
WEIGHT(Kg)
CAPACITY£¨KW£©
DimensionDxWxH
WEIGHT£¨Kg£©

3.7
600x800x1800
500(include battery)
93
£¨600x800¡Á2260£©x2£¨mainframe£©
750x2

5.5
700(include battery)
110
800x2

6
750(include battery)
120
850x2

7.5
600¡Á800¡Á2260
800(include battery)
132
£¨600x800x2260£©x3£¨mainframe£©
580x3

11
800¡Á1000¡Á2260
950(include battery)
150
610x3

15
1350(include battery)
160
640x3

18.5
600¡Á800¡Á2260

(mainframe)
490
187
660x3

22
500
200
700x3

30
520
220
710x3

37
580
250
720x3

45
620
280
(800x1000x2260)x3£¨mainframe£©

55
700
315
730x3

75
(600x800x2260)x2(mainframe)
650¡Á2
400
750x3

80
700¡Á2
500
780x3

NOTE: the series not include DC fire protective, if need you must put forward, exceed 11KW, according to backup time we decide the amount of battery cabinet, exceed 120KW, it need configure charger cabinet additional(600¡Á800¡Á2260). Download EPS PDF depliant (296KB)